Product Feature
1. Corrosion resistance: made of medical stainless steel, with much stronger corrosion resistant and rust-proof than any ordinary steel, suitable for varous high-temperature & high-pressure sterilization methods.
2. Much safer: with a unique angle-locking positioning hole to ensure the puncture direction in the long axis of the ultrasound image exactly match puncture guideline, and the short axis of the image also undergoes rigorous accuracy tests to fully guarantee the safety of puncture.
3. Easy to use: with unique locking positioning hole and a peticular large-diameter nut, easy to disassembly, and to separate the needle from the needle bracket
4. High reliability: Integral, large-part design, connecting parts tightly welded to eliminate the risk of missing small compoents; joints and connections reinforced to avoid any possible breakage.
5. High stability and high accuracy: Well matching with the probe housing for a tight connection, no deformation and high-accuracy operation ensured after a long-term use.
6. Superb glossy appearance: surface treatment purely by hand, smooth edge and corner for a safer and more comfortable use; simple and compact design to prevent any dust and dirt.
For use with SAMSUNG MEDISON ultrasound transducer
Samsung linear array ultrasound probe L3-12A
Samsung linear array ultrasound probe LA3-12A
Samsung linear array ultrasound probe LA3-14AD
Samsung linear array ultrasound probe L5-13/50
Samsung linear array ultrasound probe LA2-14A
Our biopsy needle guide covers at least the following brands, please consult with our salesperson for your specific needs
GE PHILIIPS SIEMENS CANON TOSHIBA FUJIFILM HITACHI ALOKA SonoSite esaotte Alpinion bk Samsung Medison Mindray SonoScape EDAN Wisonic VINNO SIUI Terason SUPERSONIC ULTRASONIX UNIMAGING Neusoft ZONARE ECM EZONO FUKUDA KONICA MINOLTA and others
For use with SAMSUNG ultrasound transducers |
Convex probe (Abdominal) |
Micro-convex probe |
High-frequency Linear probe (Superficial) |
Endocavity probe |
Phased Array (Cardiology) |
4D Volume probe |
Biplane probe |
CA1-7S |
CF4-9 |
LA4-18A |
3D4-9 |
PA1-5A |
CV1-8A |
|
CA1-7SD |
|
LA4-18AD |
3D4-9ES |
P3-8CA |
CV1-8AD |
|
C2-5 |
|
LA3-16A |
NEV4-9ES |
PA3-8B |
V4-8 |
|
CA3-10A |
|
LA3-16AD |
NER4-9ES |
P1-4 |
VE4-8 |
|
C2-8A |
|
LF5-13 |
E3-12A |
PE2-4 |
3D4-9 |
|
CA2-8A |
|
LA4-18B |
EC4-9/10ED |
|
3D4-9ES |
|
CA2-8AD |
|
LA4-18BD |
EC4-9/13CD |
|
V5-9 |
|
CA2-9A |
|
L3-12A |
EC4-9/10R |
|
EV3-10B |
|
CA2-9AD |
|
LA3-12A |
EC4-9ED |
|
|
|
CF2-8 |
|
LA3-14AD |
miniER7 |
|
|
|
SC1-6 |
|
L5-13/50 |
EV2-10A |
|
|
|
CA1-7A |
|
LA2-14A |
EA2-11AR |
|
|
|
CA1-7AD |
|
LN5-12 |
EA2-11AV |
|
|
|
C3-7ED |
|
LE5-12 |
EA2-11ARD |
|
|
|
C3-71M |
|
9L |
EA2-11AVD |
|
|
|
C3-7EP |
|
9L-D |
EA2-11ARE |
|
|
|
C2-8 |
|
9L-RS |
EA2-11AVE |
|
|
|
CN2-8 |
|
HL5-12ED |
EA2-11B |
|
|
|
C2-8-N |
|
LM4-15B |
EC4-9IS |
|
|
|
C2-8N |
|
LM4-15BD |
EC4-9ES |
|
|
|
C1-4EC |
|
L5-13 |
ER4-9ES |
|
|
|
C2-6 |
|
L5-13IS |
ER4-9/10ED |
|
|
|
C2-6IC |
|
L7-16IS |
EV4-9/10ED |
|
|
|
CS1-4 |
|
L7-16 |
EVN4-9 |
|
|
|
|
|
L3-8 |
EV4-9 |
|
|
|
|
|
LN5-12/40 |
ER4-9 |
|
|
|
|
|
|
EC4-9 |
|
|
|
|
|
|
EC4-9ED |
|
|
|
|
|
|
V5-9 |
|
|
|
|
|
|
EV3-10B |
|
|
|
|
|
|
VR5-9 |
|
|
|

For use with Samsung ultrasound transducer LA3-16A LA3-16AD LF5-13 biopsy needle guide, reusable needle adapter, biopsy needle bracket
For use with Samsung ultrasound transducer C2-6 C2-6IC biopsy needle guide, reusable needle adapter, biopsy needle bracket
For use with Samsung ultrasound transducer C2-8 CN2-8 C2-8-N C2-8N biopsy needle guide, reusable needle adapter, biopsy needle bracket
For use with Samsung ultrasound transducer CA1-7A CA1-7AD biopsy needle guide, reusable needle adapter, biopsy needle bracket
For use with Samsung ultrasound transducer CA1-7S CA1-7SD biopsy needle guide, reusable needle adapter, biopsy needle bracket
For use with Samsung reusable needle guide for endocavity transducer EA2-11AR EA2-11AV reusable biopsy needle adapter, biopsy needle bracket (for Urology biopsy)
For use with Samsung reusable needle guide for endocavity transducer EA2-11AR EA2-11AV EA2-11ARD EA2-11AVD reusable biopsy needle adapter, biopsy needle bracket (for OB & GYN biopsy)
Reusable biopsy needle bracket, needle guide For use with Samsung linear ultrasound transducer L3-12A LA3-12A LA3-14AD L5-13/50 LA2-14A
Reusable biopsy needle bracket, needle guide reusable biopsy needle adapter For use with Samsung ultrasound transducer LN5-12 LE5-12
Reusable needle adapter, needle guide For use with CANON TOSHIBA transvaginal transducer PVF-641VT PVM-651VT PVN-661VT PVQ-641V PVT-661VT PVG-630v
For use with GE General Electric reusable needle guide for ultrasound transducer C1-6-D, C1-6VN-D biopsy needle bracket, biopsy adapter
For use with GE General Electric reusable needle guide for endocavity ultrasound transducer E7C-RC biopsy needle bracket, biopsy adapter
Reusable biopsy needle guide for use with PHIILIPS ultrasound endocavity transducer C10-4ec reusable needel adapter, bipsy needle bracket
For use with Samsung Medison reusable biopsy needle guide for endocavity transducer EVN4-9, ER4-9, EC4-9, ER4-9/10ED, EV4-9/10ED reusable needle adapter, biopsy needle bracket

For use with Canon Toshiba reusable needle adapter for convex ultrasound transducer PVT-375BT PVT-375AT PVT-375AX PVT-375ST PVU-375BT PVT-375SC biopsy needle guide, biopsy needle bracket
For use with Canon Toshiba reusable needle adapter for endocavity ultrasound transducer PVT-781VT PVT-781VTE PVU-781VT,PVU-781VTE biopsy needle guide, biopsy needle bracket